SimMan
SimMan is a portable and advanced patient simulator for team training. It has realistic anatomy and clinical functionality and provides simulation-based education to challenge and test participants' clinical and decision-making skills during realistic patient care scenarios.
SimBaby
SimBaby is an advanced infant simulator for team training with realistic anatomy and clinical functionality and allows learners to practice and perfect their skills in a risk-free environment.
Nursing Anne
Nursing Anne is an efficient, effective, flexible mannequin for clinical training in women's health, obstetrics, post-partum, wound assessment and care, and general patient assessment and care.
The key features of Nursing Anne are:
- Head with anatomical landmarks, trachea and oesophagus, along with simulated lungs and stomach allow the practice of many procedures, including NG, OG, tracheal care and suctioning
- Normal and abnormal heart, breath, and bowel sounds, and fetal heart tones for auscultation
- Extensive library of rhythm variants for ECG interpretations using standard clinical monitors
Instructor-controlled blood pressure arm allows for realistic palpation and auscultation. Systolic and diastolic pressures, auscultatory gap, and volume are variable
- Articulating IV arm allows for practice of IV cannulation, medication administration, and site care and maintenance
Practice medication dose calculations and administration through intramuscular injections at the deltoid, gluteal, ventrogluteal, and thigh sites
- Optional modules can be added for breast examination, post-surgical mastectomy care, fundus massage skills, and assessment and care of wounds and surgical incisions
Nursing Kelly
Nursing Kelly is a mannequin designed for scenario-based training of the care and management of a wide variety of in-hospital patients.
The key features of Nursing Kelly are:
- Head with anatomical landmarks, trachea and oesophagus, and simulated lungs and stomach, allow the practice of many procedures, including NG, OG, tracheal care and suctioning
- Students can auscultate normal and abnormal heart, breath and bowel sounds using a standard stethoscope.
- Instructor-controlled blood pressure arm allows for realistic palpation and auscultation. Systolic and diastolic pressures, auscultatory gap, and volume are variable
- IV cannulation, medication administration, site care and maintenance are allowed in the antecubital area and the dorsum of the hand, accessing the median, basilic, and cephalic veins
- Ability to practice medication dose calculations and administration through intramuscular injections at the deltoid, gluteal, ventrogluteal, and thigh sites
- Realistic male and female urinary catheterization and enema procedures may be performed with fluid return
- Wound modules can be added to create realistic scenarios for wound assessment and care
Resus Anne with skills guide and Resus Anne with reporter
The key features of Resus Anne are:
- Natural obstruction of the airway allows students to learn the important technique of opening the airway so that in a real-life situation they know how to effectively administer air to the victim
- Head tilt/chin lift and jaw thrust allows students to correctly practice airway manoeuvres necessary when resuscitating a real victim
- Occluded airway with hyperextension stresses proper head position
- Realistic resistance for chest compressions allow the students to experience the amount of pressure needed to perform proper chest compressions in a real life situation
- Anatomically correct landmarks and sternal notch allow the students to practice identification of all anatomical landmarks relevant to adult CPR
- Articulating arms, legs, and head allow realistic weight and handling of an adult during obstructed airway manoeuvres
Carotid pulse simulation to realistically check for pulse
- Disposable non-rebreathing airways are suitable for use by more than one student during class and are quick and easy to change after each training session
- SkillReporter CPR performance module provides immediate objective feedback on ventilation duration and volume, compression depth, and hand position, and allows a comprehensive printed report for student performance documentation and debriefing
- Removable/reusable faces allow each student to have their own mouth-to-mouth face and offers easy after class cleaning and sanitation
Little Anne adult CPR mannequins
The key features of Little Anne are:
- Oral and nasal passages allow realistic nose pinch required for mouth-to-nose ventilation
- Natural obstruction of the airway allows students to learn the important technique of opening the airway
- Head tilt/chin lift and jaw thrust allow students to correctly practice all manoeuvres necessary when resuscitating a real victim
- Realistic airway function means that the airway remains obstructed without proper head tilt/chin lift or jaw thrust. Chest rise is seen with correct ventilations
- Anatomically correct landmarks and sternal notch allow the student to practice identification of all anatomical landmarks relevant to adult CPR
- Audible feedback reinforces correct compression depth. An optional "clicker" feature signals the correct compression depth
- Realistic chest compression resistance allows the students to experience the amount of pressure needed to perform proper chest compressions in a real-life situation
- Economical disposable airways for quick and easy clean-up
- Removable and reusable faces for convenient and affordable maintenance
Little Junor child CPR mannequins
They key features of Little Junior are:
- Oral and nasal passages allow realistic nose pinch required for mouth-to-nose and mouth-to-mouth ventilation
- Natural obstruction of the airway allows students to learn the important technique of opening the airway. Abdominal thrusts can also be practiced
- Head tilt/chin lift and jaw thrust allow students to correctly practice all manoeuvres necessary when resuscitating a real victim
- Realistic airway function means that the airway remains obstructed without proper head tilt/chin lift or jaw thrust. Chest rise is seen with correct ventilations
- Anatomically correct landmarks and sternal notch allow the student to practice identification of all anatomical landmarks relevant to child CPR
- Audible feedback for chest compressions reinforces correct compression depth with an optional "clicker" feature
- Realistic chest compression resistance allows the students to experience the amount of pressure needed to perform proper chest compressions in a real-life situation
- Economical disposable airways for quick and easy clean-up
- Removable and reusable faces for convenient and affordable maintenance
Baby Anne baby CPR mannequins
The key features of Baby Anne are:
- Oral and nasal passages allow realistic nose pinch required for mouth-to-nose ventilation
- Natural obstruction of the airway allows students to learn the important technique of opening the airway
- Head tilt/chin lift and jaw thrust allow students to practice correctly all manoeuvres necessary when resuscitating a real patient
- Realistic chest compliance means students can experience the proper technique required for chest compressions on infants
- Foreign-body airway obstruction feature allows the release of a foreign-body obstruction to be practiced through back blows and chest-thrust techniques
- Economical disposable airways for quick and easy clean up
- Removable and reusable faces for convenient and affordable maintenance
Blood pressure training arms
They key features of the blood pressure training arms are:
- Palpable antecubital pulse
- Blood Pressure Trainer with LCD guided operation
- Systolic, diastolic, heart rate and auscultatory gap are programmable
- Representation of both systolic and diastolic pressures
- Indication of gauge reading as pressure is increased or decreased
- Adjustable volume
Nursing Kid
The key features of Nursing Kid are:
- Head with anatomical landmarks, trachea, and oesophagus along with simulated lungs and stomach allow the practice of many procedures, including NG, OG, tracheal care and suctioning, and insertion, securing and care of endotracheal tubes
- Allows for the auscultation and diagnosis of normal and abnormal heart, breath and bowel sounds
- Bilateral deltoid, bilateral thigh, gluteal intramuscular injections possible
- Articulating IV arm allows for practice of IV cannulation, medication administration and site care and maintenance
- Presents normal and abnormal heart, breath and bowel sounds for auscultation
- Pre-programmed and instructor-controlled scenarios aid in standardising teaching
If you would like further information or you would like to request a booking for this facility, please email us or call us on +44 (0)1332 592326.